1993 C-Aire S175 Baseplate Fire Protection Air Compressor
Annual service for a Grantsburg school woodworking shop included repairs to its C-Aire 7.5 HP 80 gallon compressor's sight glass, high-pressure jug gasket, suction valve, drains, and regulator.

The school needed air for woodworking tools, spray finishing, and general shop use within its annual maintenance budget. Inspection found leaks at the sight glass, high-pressure jug gasket, float drains, and pressure switch. A worn suction valve, faulty moisture minder drain hose, and failing regulator also needed attention.
We changed the oil, oil filters, air filters, inline filters, and filter desiccant. Repairs addressed the sight glass, jug gasket, pressure switch, drain hose, and regulator; the suction valve and float drains were replaced. We inspected belts and electrical components, cleaned the breather and cooler, and tested the drains.
All issues resolved in a single service visit. Safe, reliable compressed air restored for the school shop program with predictable annual maintenance costs that fit the school budget.